When it comes to keeping heavy vehicles and stationary power applications running efficiently – whether it’s a battery-electric bus, a fuel-cell-powered truck, or even a hydrogen combustion excavator – thermal management is one of the most critical systems. And at the heart of that system? The electric water pump.
Gone are the days when water pumps were purely mechanical, driven by engine belts. In modern battery-electric (BEV), fuel-cell electric (FCEV), hybrid, and even internal combustion engine (ICE) vehicles, electric water pumps play a crucial role in moving coolant where it’s needed to regulate temperatures and protect components.
In this article, we’ll explain how electric water pumps work, why they’re growing in popularity, and their role in powertrain cooling, cabin HVAC, and complete systems.
Whether it’s BEVs, FCEVs, or traditional ICE vehicles, powertrain components need cooling and cabins need HVAC. Cooling batteries, fuel cells, motors, and power electronics while ensuring effective cabin heating is just as important today as it was decades ago. What has changed, however, is the type of water pump being used.
For years, mechanical water pumps have been the cornerstone of vehicle cooling systems – and they’re still widely used today, especially in ICE vehicles, thanks to their simplicity and affordability. However, with electrification on the rise, electric water pumps are becoming the preferred choice, particularly in BEVs, FCEVs, and hybrids.
In the next section, we’ll take a look at how electric water pumps work and why they are in such high demand.
A thermal management system in a heavy vehicle or industrial application typically consists of multiple closed-loop coolant circuits, each serving a specific function:
At its core, an electric water pump is a compact, electronically controlled pump that moves coolant (typically a water-ethylene glycol mix) through these heating and cooling circuits, regulating heat transfer.
Unlike belt-driven mechanical pumps, electric water pumps are not tied to engine speed, meaning they can operate precisely when and where needed, improving efficiency across all types of vehicles—from fully electric buses to hybrid construction machinery.
Two key factors determine how well heat is transferred in a cooling or heating circuit: Flow and pressure.
Flow rate (measured in litres per minute, or LPM) determines how much coolant moves through the system, while pressure (measured in bars or psi) ensures it reaches every component effectively. Electric water pumps excel at balancing these factors for optimal heat transfer.
In particular, there are two major advantages that electric water pumps offer that make them superior in modern thermal management systems.
Balancing flow rate and pressure is critical to system performance. It is a topic we’ll explore in more detail when we explore how to choose the right electric water pump for your BEV or FCEV, covering key specifications and application requirements. Sign up to our Thermal Academy newsletter and be the first to find out when it's available.
Traditional mechanical water pumps are belt-driven, meaning their performance is tied to engine RPM. This simple design, however, can lead to significant inefficiencies:
Electric water pumps eliminate this issue by running independently of the engine, which is why many modern ICE vehicles opt for them. And, in BEV and FCEV applications, where no engine is present and efficiency directly impacts range and performance, electric water pumps are essential.
Beyond operating independently, electric water pumps enable real-time, dynamic control of coolant flow – delivering just the right amount of cooling or heating when needed.
This is achieved through two common control methods:
This ability to control flow dynamically ensures that every cooling and heating circuit operates at peak efficiency, supporting battery longevity, powertrain reliability, and passenger comfort.
The result? More energy-efficient, complex thermal management systems that only circulate coolant where and when it is needed.
Grayson’s Magnetic Drive Electric Water Pump features either CAN or PWM control, enabling dynamic flow rate control.
Now that we understand the fundamentals and advantages of electric water pumps, let’s dive into how electric water pumps work within powertrain cooling, cabin HVAC, and multi-circuit systems.
One of the core functions of an electric water pump is powertrain cooling. In EVs and FCEVs, this means maintaining optimal temperatures for:
In some systems, a single pump may handle both battery and motor cooling, while in more advanced setups, like our Vehicle CTMS, dedicated cooling loops provide independent temperature control for each component.
Beyond powertrain cooling, electric water pumps are essential for cabin climate control, ensuring efficient heating and defrosting. In cabin and passenger HVAC systems, they:
In some advanced systems, thermal energy can be transferred between circuits via heat exchangers and intelligent control software to optimise efficiency and performance. This gives the opportunity for waste heat to be recycled and redistributed to other areas of the vehicle, reducing the need to rely on auxiliary heat sources that consume more energy.
For example, in our Vehicle CTMS, one coolant circuit handles battery heating whilst another is responsible for powertrain, and a third refrigerant circuit manages the cabin HVAC. By dynamically controlling the flow of this coolant and through the clever use of heat exchangers and indirect condensing, heat is efficiently transferred to different circuits, providing efficiency and packaging flexibility to OEMs designing new applications.
We’ll explore direct vs. indirect condensing in more detail in our next article, but for now, it’s important to recognise that electric water pumps play a key role in managing these interconnected systems.
Electric water pumps are more than just a component – they’re the backbone of modern thermal management systems, ensuring efficiency, reliability, and comfort in heavy vehicles and stationary power applications. Whether it’s cooling a battery pack, heating a cabin, or managing multi-circuit systems, their precision and adaptability make them indispensable in today’s electrified world.
In our next article, we’ll take a closer look at direct vs. indirect condensing and how these methods shape thermal efficiency. Until then, why not explore how Grayson’s electric water pumps can elevate your thermal management system or get in touch with our team to learn more.
In today’s evolving landscape of electrified and hybrid power systems, efficient thermal management is no longer optional—it’s essential. Whether it’s for electric buses, trucks, or stationary power systems, cooling is critical to maintaining performance, extending component lifespan, and preventing overheating.
As power demands rise, so does the need for robust cooling systems capable of handling the increased heat generated by electric powertrains, batteries, and power electronics. However, not all cooling systems are the same. Cooling technologies for heavy vehicles and stationary power applications generally fall into two categories: active cooling and passive cooling.
In this Grayson Thermal Academy blog, we will break down what active and passive cooling systems are, how they work, and explore which type you may need for your application.
An example of a passive cooling system:Â Grayson 400V AC Hydrogen Fuel Cell Cooler developed for stationary power generation applications
Passive cooling relies on natural heat dissipation with minimal energy input (i.e. the fans blowing air or pumps to circulate water). It operates using the principles of heat transfer through conduction, convection, or radiation, when external conditions allow for it.
However, passive cooling is only viable when the ambient temperature is lower than or close to the target operating temperature. In such cases, heat can be naturally rejected into the surrounding air or environment.
In moderate climates, where the ambient temperature is below the target temperature of the coolant, passive cooling can offer some valuable benefits.
One of the biggest advantages is energy efficiency—since minimal power is required, passive cooling helps conserve energy, making it especially beneficial for electrified vehicles and machinery where reducing power draw can extend range.
Passive cooling systems also have fewer components, resulting in lower upfront costs and reduced maintenance over time. For example, our Cooler Range uses brazed aluminium heat exchangers combined with electric fans to provide passive cooling for power electronics, traction motors, hydrogen fuel cells, and traditional combustion engines.
Figure 1: Typical Passive Cooling Cycle for a Heavy Vehicle
However, if the ambient temperature rises above the target operating temperature, passive cooling alone would no longer be sufficient to meet a system’s or space’s cooling requirements, and active cooling would be required.
A typical passive cooling system includes components like heat exchangers, radiators, pumps, and fans.
Heat generated by an application’s powertrain components is transferred to a coolant fluid (water-glycol, for instance) and circulated through the system. The coolant moves through radiators or heat exchangers, where the heat is dissipated into the air, often with the help of electric fans to improve airflow.
Understanding how to determine which active or passive cooling system you may need for your heavy vehicle or stationary power application is a a topic we’ll explore in more detail in upcoming blogs. Sign up to our Thermal Academy newsletter and be the first to find out when they are available.
Active cooling solutions go beyond natural heat dissipation by using external energy and more complex components to actively remove heat, making them essential when ambient temperatures are higher than a system’s target temperature.
These systems rely on powered mechanisms like compressors and refrigerant cycles to transfer heat out of the system, ensuring efficient cooling even in extreme environments or under heavy heat loads. A common example is a BTMS (Battery Thermal Management System), which can cool a high voltage battery pack to the target temperature (the set point) even when the ambient temperature is high.
Active cooling typically involves refrigerant-based systems. A compressor circulates refrigerant through a cycle that absorbs heat from components and releases it into the environment (see figure 2). This enables active cooling to maintain a lower coolant temperature than the ambient air, ensuring optimal performance even when outside temperatures are significantly higher.
This is often the case with high-capacity components like batteries or vehicle cabins in hot weather. Heat is transferred to the refrigerant, which absorbs and carries it through a cycle where it is compressed, condensed, and eventually released through a heat exchanger or condenser.
Figure 2: Example of a Refrigerant-Based Cooling System
Example of an Active Cooling System: Grayson’s Compact Battery Thermal Management System
Unlike passive cooling, which is limited by the surrounding ambient temperature, active cooling can maintain a system’s temperature well below the ambient air. This makes it indispensable in hot or tropical environments where the ambient temperature exceeds the system’s target temperature.
In addition to providing air conditioning for drivers and passengers, active cooling systems can also deliver precise, constant temperature control for powertrain components. For example, our Battery Thermal Management Systems (BTMS) constantly monitors and dynamically adjusts cooling requirements in real-time, based on parameters such as coolant flow, refrigerant flow, and fan speed. This ensures that temperature-sensitive batteries operate within their optimal range at all times, regardless of external conditions.
By contrast, passive cooling systems, which rely on natural heat dissipation, do not offer this level of precision and are less capable of managing rapid or significant temperature changes.
Figure 3: Cooling ladder for BTMS Cooling/Heating Functions
The choice between active or passive cooling depends on several factors, including ambient temperature, target coolant temperature, and coolant flow rate. For example, figure 3 shows which cooling or heating function can be employed on a BTMS, dependant on the outside ambient.
Passive cooling is often sufficient when the ambient temperature is lower than or close to the target coolant temperature, allowing natural heat dissipation to occur efficiently. However, when external conditions become more extreme — such as when the ambient temperature exceeds the system’s operating temperature — passive cooling alone cannot keep the system within the desired limits.
Coolant flow also plays a key role in this decision. High heat loads require greater coolant flow to transfer heat away from components effectively. If the flow rate is too low, even an active cooling system may not maintain the desired temperature. Conversely, a high flow rate may prevent the heat transfer to the coolant. Balancing flow rate is essential to achieving optimal cooling, especially in high-demand applications.
Ultimately, the choice between active and passive cooling depends on the specific conditions of your application. In milder climates and lower-load scenarios, passive cooling may suffice. However, for high-performance systems, hot environments and conditions, or where precise temperature control is required, active cooling would be more suitable.
In some applications, a combination of both active and passive cooling offers the ideal balance between efficiency and performance. Systems like our BTMS feature multi-stage cooling, where both passive and active cooling modes are available. The system adapts to varying ambient temperatures and heat loads, with passive cooling operating in mild conditions and active cooling taking over when the temperature rises or heat load increases. This ensures the BTMS is always using the most efficient and suitable cooling option available.
Our Complete Thermal Management System (CTMS) takes this approach a step further, delivering battery thermal management, power electronics cooling, and cabin HVAC in a single unit. It uses both active and passive cooling circuits—passive cooling handles heat dissipation for some circuits while active cooling manages others, depending on ambient temperature and the specific requirements of the system. For instance, it can cool the cabin while simultaneously cooling the powertrain and maintaining optimal battery temperature, all thanks to its indirect condensing system.
If you’re interested in learning more on indirect condensing, we’ll be diving deeper into the topic in an upcoming blog post.Â
Ultimately, finding the right balance depends on the specifics of your application—whether it’s the ambient environment, target temperature, or cooling demand. Whether you need a fully active solution, a purely passive system, or a hybrid like the BTMS or CTMS, Grayson offers a broad portfolio to help you achieve the best performance under any condition.
Contact our team today to discuss your specific cooling requirements with our thermal management experts, and don’t forget to sign up for our upcoming newsletter to stay informed on the latest innovations and updates.
Let’s consider a scenario where a vehicle’s battery pack needs to be kept at 25°C using a liquid cooling system, and the vehicle is operating in an environment where the ambient temperature is 15°C. In this case, passive cooling would be sufficient. The surrounding air is cooler than the target coolant temperature, allowing natural heat dissipation.
However, if the ambient temperature rises to 40°C, passive cooling alone would be insufficient. The air is too warm to cool the system effectively, so active cooling is required. A liquid battery chiller, such as our BTMS, would use a refrigerant-based system to actively pump heat out of the coolant and reject it into the hot ambient air.
Cooling Applied: Cabin HVAC
Now, let’s consider the cooling requirements for an operator’s cabin in heavy machinery, such as an excavator. In an ambient temperature of 20°C, passive cooling could be sufficient to maintain a comfortable cabin temperature for the driver, as the external air is close to the desired temperature.
However, in hotter environments, such as when the excavator is operating in an ambient temperature of 35°C or higher, active cooling becomes necessary. A cabin air conditioning system would actively lower the temperature by removing heat from the cabin and expelling it into the external environment via a refrigerant system.